Victron 6-35VDC Smart BatteryProtect 12/24V 220A w/Bluetooth BPR122022000
Victron 6-35VDC Smart BatteryProtect 12/24V 220A w/Bluetooth BPR122022000
VSBP-220
$141.09
Enter your e-mail address to be notified when product is in stock
Notify Me!
Seller Info
Battery Doctor (3448)
Seller Accepts
Shipping Policy
Orders are generally dispatched the following business day. Standard shipping times are usually 1-3 business days
Return Policy
Money Back / Exchange within 14 days
Description
Stock imported on demand. Please allow up to 5 business days lead time prior to dispatch to your address.
 
Description 6-35VDC Smart BatteryProtect 12/24V 220A w/Bluetooth BPR122022000
Application Smart Battery Protector
Original Brand Victron Energy BPR122022000
Width 120mm
Height 62mm
Length/Breadth/Depth 123mm
Weight 800g
Brand

 

6-35VDC Smart BatteryProtect 12/24V 220A

Protects the battery against excessive discharge and can be used as a system on/off switch

The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.
The on/off input can be used as a system on/off switch.

12/24V auto ranging
The Smart BatteryProtect automatically detects system voltage one time only.

Bluetooth: programming made easy
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.
Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual).
If required, Bluetooth can be disabled.

A special setting for Li-ion batteries
In this mode the BatteryProtect can be controlled by the VE.Bus BMS.
Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.

Ultra-low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown.
Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.

Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.

Ignition proof
No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds.
Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage

VictronConnect Compatible

VictronConnect lets you get live status information and configure any Victron products

which either have Bluetooth built in, or are connected to a VE.Direct Bluetooth Smart Dongle 

or VE.Direct to USB Interface 

 
 
Find out more about VictronConnect here or download the Apps below

 

 

 

   
Reviews (0)
Currently there are no reviews for this product.
Questions
Currently there are no questions for this product.
<-- Digital window verification 001 -->